  "topic": [
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Fire: Structural fire resistance"
    }
  ],
  "references": [
    {
      "@type": [
        "npg:Document"
      ],
      "@id": "#ref:10.1007/s10694-016-0646-7",
      "refType": "IsSupplementTo",
      "location": "https://doi.org/10.1007/s10694-016-0646-7",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/bib/v0.7#/definitions/DCiteReference"
      ],
      "title": "Engineering Approach for Designing a Thermal Test of Real-Scale Steel Beam Exposed to Localized Fire",
      "issued": "2017-01-13",
      "citation": "Zhang, C., Choe, L., Gross, J., Ramesh, S., & Bundy, M. (2017). Engineering Approach for Designing a Thermal Test of Real-Scale Steel Beam Exposed to Localized Fire. Fire Technology, 53(4), 1535\u00e2\u0080\u00931554. doi:10.1007/s10694-016-0646-7\n"
    }
  ],
  "keyword": [
    "steel beam; localized fire; thermal and mechanical behavior; experimental test"
  ],
  "landingPage": "https://data.nist.gov/od/id/59145AB0040F183BE0531A5706818E571856",
  "title": "Measurement of the Behavior of Steel Beams under Localized Fire Exposure",
  "theme": [
    "Fire: Structural fire resistance"
  ],
  "programCode": [
    "006:052"
  ],
  "description": [
    "A total of nine localized fire tests on steel beams were designed and conducted in the National Fire Research Laboratory as part of its commissioning project, including thermal tests (Tests 1 through 5) and four-point bending test at ambient (Test 6) and elevated temperatures (Tests 7 through 9). All the tested specimens were nominally 6.2-m long W16\u00d726 beams made of ASTM A992 steel. Each specimen was supported by one of the two following connections: (i) simple support (Tests 1 through 8), and (ii) double-angles bolted to laterally braced support columns (Test 9). The midspan of each specimen was exposed to an open-flame fire using the 1-m2 natural gas burners. The burner was located 1.1 m below the bottom flange of the beam at midspan. A four-point flexural loading scheme was used to apply concentrated forces at two locations 2.44 m apart around midspan. The data included temperatures, the heat release rates from the burner, and structural measurements including forces, displacements and strains. The Type B standard uncertainties in various measurements were also included. Overall, the test results showed that the heating rate of the specimen was sensitive to the prescribed heat release rate-time relationship. However, the thermal gradient developed in the fire-exposed cross sections of the beam never achieved linearity under the localized fire exposure. Regardless of the connection types and fire conditions (i.e., steady-state or transient-state fire), the beams exhibited a similar behavior and failure mode. When subjected to combined fire and flexural loads, the beam specimens exhibited the lateral-torsional buckling followed by runaway vertical displacements at midspan. Additional details of experimental procedures and uncertainty analysis for this experimental series are provided in the following publications: 1) Zhang, C., Choe, L., Gross, J., Ramesh, S., Bundy, M. (2017). Engineering Approach for Designing a Thermal Test of Real-scale Steel Beam Exposed to Localized Fire. Fire Technology, Vol 53, Issue 4, pp 1535-1554. DOI: 10.1007/s10694-016-0646-7 2) Choe, L., Ramesh, S., Zhang, C., Gross, J. (2016). The Performance of Structural Steel Beams Subjected to a Localized Fire. The 9th International Conference on Structures in Fire (SiF 16), June 8-10, 2016, Princeton, NJ."
  ],
  "bureauCode": [
    "006:55"
  ],
  "contactPoint": {
    "hasEmail": "mailto:lisa.choe@nist.gov",
    "fn": "Lisa Choe"
  },
  "accessLevel": "public",
  "@id": "ark:/88434/mds0147p62",
  "publisher": {
    "@type": "org:Organization",
    "name": "National Institute of Standards and Technology"
  },
  "doi": "doi:10.18434/mds2-1856",
  "license": "https://www.nist.gov/open/license",
  "language": [
    "en"
  ],
  "modified": "2017-08-14 00:00:00",
  "ediid": "59145AB0040F183BE0531A5706818E571856",
  "components": [
    {
      "accessURL": "https://doi.org/10.18434/M37H4G",
      "@type": [
        "nrdp:AccessPage",
        "dcat:Distribution"
      ],
      "@id": "#10.18434/M37H4G",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/AccessPage"
      ]
    },
    {
      "@id": "cmps/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx",
      "downloadURL": "https://s3.amazonaws.com/nist-midas/1856/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx",
      "mediaType": "text/plain"
    },
    {
      "@id": "cmps/1856",
      "@type": [
        "nrdp:Subcollection"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/Subcollection"
      ],
      "filepath": "1856"
    },
    {
      "@id": "cmps/1856/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx",
      "@type": [
        "nrdp:DataFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "1856/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx",
      "mediaType": "text/plain",
      "downloadURL": "https://s3.amazonaws.com/nist-midas/1856/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx"
    },
    {
      "@id": "cmps/1856/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx",
      "@type": [
        "nrdp:DataFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "1856/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx",
      "mediaType": "text/plain",
      "downloadURL": "https://s3.amazonaws.com/nist-midas/1856/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx"
    },
    {
      "@id": "cmps/1856/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx.sha256",
      "@type": [
        "nrdp:DataFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "1856/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx.sha256",
      "mediaType": "text/plain",
      "downloadURL": "https://s3.amazonaws.com/nist-midas/1856/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx.sha256"
    },
    {
      "@id": "cmps/1856/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx.sha256",
      "@type": [
        "nrdp:DataFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "1856/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx.sha256",
      "mediaType": "text/plain",
      "downloadURL": "https://s3.amazonaws.com/nist-midas/1856/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx.sha256"
    },
    {
      "@id": "cmps/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx",
      "downloadURL": "https://s3.amazonaws.com/nist-midas/1856/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx",
      "mediaType": "text/plain"
    },
    {
      "@id": "cmps/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx.sha256",
      "@type": [
        "nrdp:ChecksumFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "filepath": "NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx.sha256",
      "downloadURL": "https://s3.amazonaws.com/nist-midas/1856/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx.sha256",
      "algorithm": {
        "tag": "sha256",
        "@type": "Thing"
      },
      "describes": "cmps/NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx",
      "description": "SHA-256 checksum value for NFRL_LocalizedFireTest_SteelBeam_09012017.xlsx",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/ChecksumFile"
      ],
      "mediaType": "text/plain"
    },
    {
      "@id": "cmps/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx.sha256",
      "@type": [
        "nrdp:ChecksumFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "filepath": "NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx.sha256",
      "downloadURL": "https://s3.amazonaws.com/nist-midas/1856/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx.sha256",
      "algorithm": {
        "tag": "sha256",
        "@type": "Thing"
      },
      "describes": "cmps/NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx",
      "description": "SHA-256 checksum value for NFRL_LocalizedFireTest_SteelBeam_08112017.xlsx",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/ChecksumFile"
      ],
      "mediaType": "text/plain"
    }
  ],
  "status": "available",
  "version": "1.0.0",
  "releaseHistory": {
    "@id": "ark:/88434/mds0147p62.rel",
    "@type": [
      "nrdr:ReleaseHistory"
    ],
    "hasRelease": [
      {
        "version": "1.0.0",
        "issued": "2017-08-14",
        "@id": "ark:/88434/mds0147p62/pdr:v/1.0.0",
        "location": "https://data.nist.gov/od/id/ark:/88434/mds0147p62/pdr:v/1.0.0",
        "description": "initial release"
      }
    ]
  },
  "annotated": "2021-11-08T21:27:44.832273",
  "revised": "2021-11-08T21:27:44.832273",
  "issued": null,
  "firstIssued": "2021-11-08T21:27:44.832273"
}