  "_schema": "https://data.nist.gov/od/dm/nerdm-schema/v0.7#",
  "@context": [
    "https://data.nist.gov/od/dm/nerdm-pub-context.jsonld",
    {
      "@base": "ark:/88434/mds2-2151"
    }
  ],
  "@type": [
    "nrdp:PublicDataResource",
    "dcat:Dataset"
  ],
  "_extensionSchemas": [
    "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/PublicDataResource"
  ],
  "@id": "ark:/88434/mds2-2151",
  "title": "Construction of a Dual-enzyme, Subzero (-30 degree C) Chromatography System and Multi-channel Precision Temperature Controller for Hydrogen-Deuterium Exchange Mass Spectrometry",
  "contactPoint": {
    "fn": "Jeffrey W. Hudgens",
    "hasEmail": "mailto:jeffrey.hudgens@nist.gov"
  },
  "modified": "2019-02-20",
  "ediid": "ark:/88434/mds2-2151",
  "landingPage": "https://data.nist.gov/od/id/mds2-2151",
  "description": [
    "This tutorial provides  mechanical drawings, electrical schematics, parts lists, STL files for 3D-printed parts, IGS files, and instructions for automated machining necessary for construction of a dual-protease, subzero, liquid chromatography system for hydrogen-deuterium exchange mass spectrometry. Electrical schematics for construction of a multi-zone temperature controller that regulate to \u00b10.1 oC are also included in this tutorial."
  ],
  "keyword": [
    "liquid chromatography",
    "hydrogen-deuterium exchange",
    "mass spectrometry",
    "precision",
    "peptide",
    "protein",
    "proteolysis",
    "proteomics",
    "reference material",
    "temperature control."
  ],
  "theme": [
    "Bioscience: Bioprocessing",
    "Chemistry: Analytical chemistry",
    "Physics: Biological physics",
    "Bioscience: Proteomics",
    "Metrology: Amount of substance"
  ],
  "topic": [
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Bioscience: Bioprocessing"
    },
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Chemistry: Analytical chemistry"
    },
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Physics: Biological physics"
    },
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Bioscience: Proteomics"
    },
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Metrology: Amount of substance"
    }
  ],
  "accessLevel": "public",
  "license": "https://www.nist.gov/open/license",
  "components": [
    {
      "accessURL": "https://doi.org/10.18434/M32151",
      "@type": [
        "nrd:Hidden",
        "dcat:Distribution"
      ],
      "@id": "#doi:10.18434/M32151"
    },
    {
      "@id": "cmps/ADDENDUM for HDX.docx.sha256",
      "@type": [
        "nrdp:ChecksumFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "filepath": "ADDENDUM for HDX.docx.sha256",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/ADDENDUM%20for%20HDX.docx.sha256",
      "algorithm": {
        "tag": "sha256",
        "@type": "Thing"
      },
      "describes": "cmps/ADDENDUM for HDX.docx",
      "description": "SHA-256 checksum value for ADDENDUM for HDX.docx",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/ChecksumFile"
      ],
      "mediaType": "text/plain",
      "size": 64,
      "valid": true,
      "checksum": {
        "hash": "43473f0e08c650901360e8581e918983a1d531007f1f362d53c841c206ed2452",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/ADDENDUM for HDX.docx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "ADDENDUM for HDX.docx",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/ADDENDUM%20for%20HDX.docx",
      "mediaType": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "format": {
        "description": "word processing document"
      },
      "description": "This addendum provides information for configuring the instrument with an 8-port valve in the Valve #2 location. The 8-port valve offers the ability to backflush the protease, trap, and analytical columns, which allows more rapid removal of protease aggregates from the top of each column. ",
      "size": 12969,
      "checksum": {
        "hash": "95c14973d20d7243313122117e87bf10e3b485cb5e2eab917062d98e6a10cbb8",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/HDX-MS Analytical Instrument.pdf.sha256",
      "@type": [
        "nrdp:ChecksumFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "filepath": "HDX-MS Analytical Instrument.pdf.sha256",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/HDX-MS%20Analytical%20Instrument.pdf.sha256",
      "algorithm": {
        "tag": "sha256",
        "@type": "Thing"
      },
      "describes": "cmps/HDX-MS Analytical Instrument.pdf",
      "description": "SHA-256 checksum value for HDX-MS Analytical Instrument.pdf",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/ChecksumFile"
      ],
      "mediaType": "text/plain",
      "size": 64,
      "checksum": {
        "hash": "3fb2feb33610ba4e143f3f4ad3b7bc9cf130bcf5f2466b63092107f7426fb383",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "valid": true,
      "title": "SHA256 File for HDX-MS Analytical Instrument for Incorporation on a Robotic Rail, Featuring Dual Enzyme Chambers and HPLC Separations at -30 degree C"
    },
    {
      "@id": "cmps/Multi-Channel Valve Controller STL files.7z",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Multi-Channel Valve Controller STL files.7z",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/Multi-Channel%20Valve%20Controller%20STL%20files.7z",
      "mediaType": "application/x-7z-compressed",
      "size": 69347,
      "checksum": {
        "hash": "5b05e48056af40eabd507bb5be8e118e273cdb593623b3ce350250a42af0362e",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "description": "This file contains the STL files for the 3D-printed parts used to construct the Multi-Channel Valve Controller",
      "title": "Multi-Channel Valve Controller STL files"
    },
    {
      "@id": "cmps/T-controller (ver 2).pdf.sha256",
      "@type": [
        "nrdp:ChecksumFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "filepath": "T-controller (ver 2).pdf.sha256",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/T-controller%20%28ver%202%29.pdf.sha256",
      "algorithm": {
        "tag": "sha256",
        "@type": "Thing"
      },
      "describes": "cmps/T-controller (ver 2).pdf",
      "description": "SHA-256 checksum value for T-controller (ver 2).pdf",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/ChecksumFile"
      ],
      "mediaType": "text/plain",
      "size": 64,
      "valid": true,
      "checksum": {
        "hash": "ea14ad9c5a5142003900c5f372193ed43bbebadc0201532af8c178d37e942974",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Multi-Channel Valve Controller.pdf.sha256",
      "@type": [
        "nrdp:ChecksumFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "filepath": "Multi-Channel Valve Controller.pdf.sha256",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/Multi-Channel%20Valve%20Controller.pdf.sha256",
      "algorithm": {
        "tag": "sha256",
        "@type": "Thing"
      },
      "describes": "cmps/Multi-Channel Valve Controller.pdf",
      "description": "SHA-256 checksum value for Multi-Channel Valve Controller.pdf",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/ChecksumFile"
      ],
      "mediaType": "text/plain",
      "size": 64,
      "checksum": {
        "hash": "948220cdd06f20e072e472527c709406a9bcf7f13e1e3471b64d9680a1175762",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "valid": true,
      "title": "SHA256 File for Multi-Channel Valve Controller"
    },
    {
      "@id": "cmps/Multi-Channel Valve Controller STL files.7z.sha256",
      "@type": [
        "nrdp:ChecksumFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "filepath": "Multi-Channel Valve Controller STL files.7z.sha256",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/Multi-Channel%20Valve%20Controller%20STL%20files.7z.sha256",
      "algorithm": {
        "tag": "sha256",
        "@type": "Thing"
      },
      "describes": "cmps/Multi-Channel Valve Controller STL files.7z",
      "description": "SHA-256 checksum value for Multi-Channel Valve Controller STL files.7z",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/ChecksumFile"
      ],
      "mediaType": "text/plain",
      "size": 64,
      "checksum": {
        "hash": "fda7057893269fdf81e029a08578ecf7d5ce6f26790c0c4415bb7ba3a2fffc91",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "valid": true,
      "title": "SHA256 File for Multi-Channel Valve Controller STL files"
    },
    {
      "@id": "cmps/Multi-Channel Valve Controller.pdf",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Multi-Channel Valve Controller.pdf",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/Multi-Channel%20Valve%20Controller.pdf",
      "mediaType": "application/pdf",
      "size": 4558922,
      "checksum": {
        "hash": "acb9401b78bd461a9d0d615674d22423619f56fc14ef4a0a118459d206601a87",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "description": "This file presents mechanical drawings, electrical schematics, parts lists, STL file inventory for 3D-printed parts, and instructions for construction of the Multi-Channel Valve Controller.",
      "title": "Multi-Channel Valve Controller"
    },
    {
      "@id": "cmps/HDX-MS Analytical Instrument STL-IGS Files.7z.sha256",
      "@type": [
        "nrdp:ChecksumFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "filepath": "HDX-MS Analytical Instrument STL-IGS Files.7z.sha256",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/HDX-MS%20Analytical%20Instrument%20STL-IGS%20Files.7z.sha256",
      "algorithm": {
        "tag": "sha256",
        "@type": "Thing"
      },
      "describes": "cmps/HDX-MS Analytical Instrument STL-IGS Files.7z",
      "description": "SHA-256 checksum value for HDX-MS Analytical Instrument STL-IGS Files.7z",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/ChecksumFile"
      ],
      "mediaType": "text/plain",
      "size": 64,
      "checksum": {
        "hash": "85e007fdb8ff73bb1ffedd1a0281e72331d28ce39e422394d201f7ee52319ccb",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "valid": true,
      "title": "SHA256 File for STL and IGS files that accompany the file, HDX-MS Analytical Instrument.pdf"
    },
    {
      "@id": "cmps/T-controller (ver 2).pdf",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "T-controller (ver 2).pdf",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/T-controller%20%28ver%202%29.pdf",
      "mediaType": "application/pdf",
      "size": 13508039,
      "checksum": {
        "hash": "b3f4ef81aafe8f0d677d1346cbc52ca7e244bb230888e0069b9de622a56d89af",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Multi-Channel T-controller.pdf",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Multi-Channel T-controller.pdf",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/Multi-Channel%20T-controller.pdf",
      "mediaType": "application/pdf",
      "size": 6496665,
      "checksum": {
        "hash": "71cc19f051ab6d2b51d6d619e1928ec06faf70ad63bdddc82daebf3086fa12e1",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "description": "This file presents mechanical drawings, electrical schematics, parts lists, STL file inventory for 3D-printed parts, and instructions for construction of the Multi-channel Temperature Controller",
      "title": "Construction information for the Multi-channel Temperature Controller"
    },
    {
      "@id": "cmps/HDX-MS Analytical Instrument STL-IGS Files.7z",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "HDX-MS Analytical Instrument STL-IGS Files.7z",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/HDX-MS%20Analytical%20Instrument%20STL-IGS%20Files.7z",
      "mediaType": "application/x-7z-compressed",
      "size": 5249122,
      "checksum": {
        "hash": "5183148214b314a1b5fd7221f5ecd4ae96612e7f9cbc4fe6ef0504b17429b069",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "format": {
        "description": "7Z"
      },
      "description": "This is the compressed file containing the STL and IGS files that accompany the file, HDX-MS Analytical Instrument.pdf.",
      "title": "STL and IGS files that accompany the file, HDX-MS Analytical Instrument.pdf"
    },
    {
      "@id": "cmps/Multi-Channel T-controller STL Files.7z",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Multi-Channel T-controller STL Files.7z",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/Multi-Channel%20T-controller%20STL%20Files.7z",
      "mediaType": "application/x-7z-compressed",
      "size": 381673,
      "checksum": {
        "hash": "b86439b61bfa290d6e1a5d39a2151bc4c728ba29f6ea8245ded2b39ae7bb65da",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "format": {
        "description": "7Z"
      },
      "description": "STL Files for parts used to construct the Multi-channel Temperature Controller",
      "title": "STL Files for parts used to construct the Multi-channel Temperature Controller"
    },
    {
      "@id": "cmps/Multi-Channel T-controller STL Files.7z.sha256",
      "@type": [
        "nrdp:ChecksumFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "filepath": "Multi-Channel T-controller STL Files.7z.sha256",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/Multi-Channel%20T-controller%20STL%20Files.7z.sha256",
      "algorithm": {
        "tag": "sha256",
        "@type": "Thing"
      },
      "describes": "cmps/Multi-Channel T-controller STL Files.7z",
      "description": "SHA-256 checksum value for Multi-Channel T-controller STL Files.7z",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/ChecksumFile"
      ],
      "mediaType": "text/plain",
      "size": 64,
      "checksum": {
        "hash": "bfc117f05ec290cdc10df9be908055cc02df9bed04a3464940492d146a49a5b6",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "valid": true,
      "title": "SHA256 File for STL Files for parts used to construct the Multi-channel Temperature Controller"
    },
    {
      "@id": "cmps/Multi-Channel T-controller.pdf.sha256",
      "@type": [
        "nrdp:ChecksumFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "filepath": "Multi-Channel T-controller.pdf.sha256",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/Multi-Channel%20T-controller.pdf.sha256",
      "algorithm": {
        "tag": "sha256",
        "@type": "Thing"
      },
      "describes": "cmps/Multi-Channel T-controller.pdf",
      "description": "SHA-256 checksum value for Multi-Channel T-controller.pdf",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/ChecksumFile"
      ],
      "mediaType": "text/plain",
      "size": 64,
      "checksum": {
        "hash": "f38563d2e2ed40021b0cf6ca3c390488b061fc2c97c087c01883d8238beae1d8",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "valid": true,
      "title": "SHA256 File for Construction information for the Multi-channel Temperature Controller"
    },
    {
      "@id": "cmps/HDX-MS Analytical Instrument.pdf",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "HDX-MS Analytical Instrument.pdf",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2151/HDX-MS%20Analytical%20Instrument.pdf",
      "mediaType": "application/pdf",
      "size": 40824749,
      "checksum": {
        "hash": "9db4aaf9c3e1d184742bfe1a4fa1e183e1e17790baab856e87d7a22bb771075f",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      },
      "description": "This file presents mechanical drawings, electrical schematics, parts lists, lists of STL files for 3D-printed parts, lists of IGS files for automated machining, and instructions for construction of the HDX-MS Analytical Instrument for Incorporation on a Robotic Rail, Featuring Dual Enzyme Chambers and HPLC Separations at -30 degree C",
      "title": "HDX-MS Analytical Instrument for Incorporation on a Robotic Rail, Featuring Dual Enzyme Chambers and HPLC Separations at -30 degree C"
    }
  ],
  "publisher": {
    "name": "National Institute of Standards and Technology",
    "@type": "org:Organization"
  },
  "language": [
    "en"
  ],
  "bureauCode": [
    "006:55"
  ],
  "programCode": [
    "006:052"
  ],
  "doi": "doi:10.18434/M32151",
  "issued": "2020-04-14",
  "references": [],
  "version": "1.2.0",
  "releaseHistory": {
    "@id": "ark:/88434/mds2-2151/pdr:v",
    "@type": [
      "nrdr:ReleaseHistory"
    ],
    "hasRelease": [
      {
        "version": "1.0.0",
        "issued": "2019-02-20 00:00:00",
        "@id": "ark:/88434/mds2-2151/pdr:v/1.0.0",
        "location": "https://data.nist.gov/od/id/ark:/88434/mds2-2151/pdr:v/1.0.0",
        "description": "initial release"
      },
      {
        "version": "1.1.0",
        "issued": "2019-02-20",
        "@id": "ark:/88434/mds2-2151/pdr:v/1.1.0",
        "location": "https://data.nist.gov/od/id/ark:/88434/mds2-2151/pdr:v/1.1.0",
        "description": "data update"
      },
      {
        "version": "1.2.0",
        "issued": "2019-02-20",
        "@id": "ark:/88434/mds2-2151/pdr:v/1.2.0",
        "location": "https://data.nist.gov/od/id/ark:/88434/mds2-2151/pdr:v/1.2.0",
        "description": "data update"
      }
    ]
  }
}