  "_schema": "https://data.nist.gov/od/dm/nerdm-schema/v0.7#",
  "@context": [
    "https://data.nist.gov/od/dm/nerdm-pub-context.jsonld",
    {
      "@base": "ark:/88434/mds2-2726"
    }
  ],
  "@type": [
    "nrdp:PublicDataResource",
    "dcat:Dataset"
  ],
  "_extensionSchemas": [
    "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/PublicDataResource"
  ],
  "@id": "ark:/88434/mds2-2726",
  "ediid": "ark:/88434/mds2-2726",
  "version": "1.0.0",
  "doi": "doi:10.18434/mds2-2726",
  "title": "Reinstatement of the NIST Field Strength Probe Calibration Service",
  "contactPoint": {
    "fn": "Matt Simons",
    "hasEmail": "mailto:matthew.simons@nist.gov"
  },
  "modified": "2022-04-05",
  "status": "available",
  "landingPage": "https://data.nist.gov/od/id/mds2-2726",
  "description": [
    "After recently completing a five year renovation, the NIST anechoic chamber for radio-frequency field strength measurements was returned to service. Tests of field probe transfer functions can now be performed from 10 kHz to 40 GHz. To validate that the chamber and measurement process maintained continuity, measurements of NIST field probes in the new chamber were compared with measurements in the chamber before renovation and in another test facility at NIST. An uncertainty analysis was carried out on the new measurement process."
  ],
  "keyword": [
    "fields strength",
    "electric field",
    "volts/meter",
    "antenna",
    "robots",
    "metrology"
  ],
  "theme": [
    "Electronics: Electromagnetics"
  ],
  "topic": [
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Electronics: Electromagnetics"
    }
  ],
  "accessLevel": "public",
  "license": "https://www.nist.gov/open/license",
  "publisher": {
    "name": "National Institute of Standards and Technology",
    "@type": "org:Organization"
  },
  "language": [
    "en"
  ],
  "bureauCode": [
    "006:55"
  ],
  "programCode": [
    "006:052"
  ],
  "components": [
    {
      "@id": "cmps/Fig3_AMTA_40GHz.csv",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Fig3_AMTA_40GHz.csv",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2726/Fig3_AMTA_40GHz.csv",
      "mediaType": "text/csv",
      "format": {
        "description": "2 column csv"
      },
      "description": "X axis is the first column, distance from calibration position in mm.\nY axis is the second column, the relative response of the probe vs the calibration position in dB.\nThis file is the RF = 40 MHz trace. ",
      "title": "Fig3_b",
      "size": 3801,
      "checksum": {
        "hash": "68f1d561b695f98baded7e462ce2b8825facf6e4742a513112e2299511323c5a",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Fig3_AMTA_500MHz.csv",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Fig3_AMTA_500MHz.csv",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2726/Fig3_AMTA_500MHz.csv",
      "mediaType": "text/csv",
      "format": {
        "description": "2 column csv file"
      },
      "description": "X axis is the first column, distance from calibration position in mm.\nY axis is the second column, the relative response of the probe vs the calibration position in dB.\nThis file is the RF = 500 MHz trace. ",
      "title": "Fig3_a",
      "size": 103,
      "checksum": {
        "hash": "d41cb8cb3bcc87abad7aff037b05bb8febfc2780c6e59e0dd24b93eb29a1fa08",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Fig2_AMTA.csv",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Fig2_AMTA.csv",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2726/Fig2_AMTA.csv",
      "mediaType": "text/csv",
      "format": {
        "description": "3 column csv"
      },
      "description": "X axis is the first column, RF frequency in MHz.\nY axis is the second column, degree of equivalence in dB.\nError bars are the third column, in dB.\nThe first 6 rows are the 8 mm probes, the last 3 rows are the 6 mm probes",
      "title": "Fig2",
      "size": 191,
      "checksum": {
        "hash": "a375fdb314cda8d7db796f96677e0eca45675703e27a3ff237a4256884c5d5ef",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/2726_README.txt",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "2726_README.txt",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-2726/2726_README.txt",
      "mediaType": "text/plain",
      "format": {
        "description": "txt"
      },
      "description": "readme file",
      "title": "README",
      "size": 2305,
      "checksum": {
        "hash": "dfdd505da8d397bb5f6b36c7d3c491ac81fff36c60c0e138b28c7ed67e5a2cdc",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    }
  ],
  "references": [
    {
      "@type": [
        "npg:Document"
      ],
      "@id": "#ref:10.23919/AMTA55213.2022.9955009",
      "refType": "IsSupplementTo",
      "location": "https://doi.org/10.23919/AMTA55213.2022.9955009",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/bib/v0.7#/definitions/DCiteReference"
      ],
      "title": "Reinstatement of the NIST Field Strength Probe Calibration Service",
      "issued": "2022-10-09",
      "citation": "Simons, M. T., Parks, C., Neylon, V., Koepke, G., & Holloway, C. L. (2022). Reinstatement of the NIST Field Strength Probe Calibration Service. 2022 Antenna Measurement Techniques Association Symposium (AMTA). https://doi.org/10.23919/amta55213.2022.9955009\n"
    }
  ],
  "annotated": "2022-11-29T19:39:59.639044",
  "revised": "2022-11-29T19:39:59.639044",
  "issued": null,