  "_schema": "https://data.nist.gov/od/dm/nerdm-schema/v0.7#",
  "@context": [
    "https://data.nist.gov/od/dm/nerdm-pub-context.jsonld",
    {
      "@base": "ark:/88434/mds2-3089"
    }
  ],
  "@type": [
    "nrdp:PublicDataResource",
    "dcat:Dataset"
  ],
  "_extensionSchemas": [
    "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/PublicDataResource"
  ],
  "@id": "ark:/88434/mds2-3089",
  "ediid": "ark:/88434/mds2-3089",
  "version": "1.0.0",
  "doi": "doi:10.18434/mds2-3089",
  "title": "Mid-infrared supermirrors with finesse exceeding 400 000",
  "contactPoint": {
    "fn": "Adam Fleisher",
    "hasEmail": "mailto:adam.fleisher@nist.gov"
  },
  "modified": "2023-10-03",
  "status": "available",
  "landingPage": "https://data.nist.gov/od/id/mds2-3089",
  "description": [
    "Data from peer-reviewed publication:  G.-W. Truong et al., Mid-infrared supermirrors with finesse exceeding 400 000, Nature Communications. For trace gas sensing and precision spectroscopy, optical cavities incorporating low-loss mirrors are indispensable for path length and optical intensity enhancement. Optical interference coatings in the visible and near-infrared (NIR) spectral regions have achieved total optical losses below 2 parts per million (ppm), enabling a cavity finesse in excess of 1 million. However, such advancements have been lacking in the mid-infrared (MIR), despite substantial scientific interest. Here, we demonstrate a significant breakthrough in high-performance MIR mirrors, reporting substrate-transferred single-crystal interference coatings capable of cavity finesse values from 200 000 to 400 000 near 4.5 microns, with excess optical losses (scatter and absorption) below 5 ppm. In a first proof-of-concept demonstration, we achieve the lowest noise-equivalent absorption in a linear cavity ring-down spectrometer normalized by cavity length. This substantial improvement in performance will unlock a rich variety of MIR applications for atmospheric transport and environmental sciences, detection of fugitive emissions, process gas monitoring, breath-gas analysis, and verification of biogenic fuels and plastics."
  ],
  "keyword": [
    "mid-infrared",
    "optical interference coatings",
    "mirrors",
    "process gas analysis",
    "greenhouse gases",
    "cavity ring-down spectroscopy",
    "optical metrology"
  ],
  "topic": [
    {
      "@type": "Concept",
      "tag": "Metrology:Optical, photometry, and laser metrology"
    },
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Physics: Optical physics"
    },
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Physics: Spectroscopy"
    },
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Chemistry: Analytical chemistry"
    },
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Environment: Greenhouse gas measurements"
    }
  ],
  "accessLevel": "public",
  "license": "https://www.nist.gov/open/license",
  "publisher": {
    "name": "National Institute of Standards and Technology",
    "@type": "org:Organization"
  },
  "language": [
    "en"
  ],
  "bureauCode": [
    "006:55"
  ],
  "programCode": [
    "006:052"
  ],
  "theme": [
    "Metrology:Optical, photometry, and laser metrology",
    "Physics: Optical physics",
    "Physics: Spectroscopy",
    "Chemistry: Analytical chemistry",
    "Environment: Greenhouse gas measurements"
  ],
  "components": [
    {
      "@id": "cmps/Fig4.xlsx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Fig4.xlsx",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3089/Fig4.xlsx",
      "mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "title": "Fig4",
      "size": 66418,
      "checksum": {
        "hash": "ae11bcf93870228c89c89352566f6b341ab9502a86b31c91c37d862fd9e60910",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/readme.txt",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "readme.txt",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3089/readme.txt",
      "mediaType": "text/plain",
      "title": "readme",
      "size": 13070,
      "checksum": {
        "hash": "91c7e850d38a3aeb7fd7c8543265c7b400c6bad49031920abb8ac623e7dbab47",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Fig2.xlsx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Fig2.xlsx",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3089/Fig2.xlsx",
      "mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "title": "Fig2",
      "size": 1762715,
      "checksum": {
        "hash": "fe3c7f53a3f5c43c923cc4fde2850a865280f635cc3bb27cc6d6e31ac0654223",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Fig5.xlsx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Fig5.xlsx",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3089/Fig5.xlsx",
      "mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "title": "Fig5",
      "size": 504017,
      "checksum": {
        "hash": "ff0ebc164f20e684d69cc153c71a85f3b5e72d24c979c55d58ea00289457c17a",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Fig3.xlsx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Fig3.xlsx",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3089/Fig3.xlsx",
      "mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "title": "Fig3",
      "size": 158908,
      "checksum": {
        "hash": "cf865d3ec0767b7719dc2dd8b8ff4638ccba8fb9b4e4c794b1e7acc8d37a4a37",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    }
  ],
  "references": [
    {
      "@type": [
        "schema:Article"
      ],
      "@id": "#ref:10.48550/arXiv.2209.09902",
      "refType": "IsSupplementTo",
      "location": "https://doi.org/10.48550/arXiv.2209.09902",
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/bib/v0.7#/definitions/DCiteReference"
      ],
      "title": "Mid-infrared supermirrors with finesse exceeding 400 000",
      "issued": "2022",
      "citation": "Truong, G.-W., Perner, L. W., Bailey, D. M., Winkler, G., Cata\u00f1o-Lopez, S. B., Wittwer, V. J., Sudmeyer, T., Nguyen, C., Follman, D., Fleisher, A. J., Heckl, O. H., &amp; Cole, G. D. (2022). <i>Mid-infrared supermirrors with finesse exceeding 400 000</i> (Version 3). arXiv. https://doi.org/10.48550/ARXIV.2209.09902"
    }
  ],
  "annotated": "2023-11-07T21:18:39.187450",
  "revised": "2023-11-07T21:18:39.187450",
  "issued": null,
  "firstIssued": "2023-11-07T21:18:39.187450"
}