  "_schema": "https://data.nist.gov/od/dm/nerdm-schema/v0.7#",
  "@context": [
    "https://data.nist.gov/od/dm/nerdm-pub-context.jsonld",
    {
      "@base": "ark:/88434/mds2-3158"
    }
  ],
  "@type": [
    "nrdp:PublicDataResource",
    "dcat:Dataset"
  ],
  "_extensionSchemas": [
    "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/PublicDataResource"
  ],
  "@id": "ark:/88434/mds2-3158",
  "ediid": "ark:/88434/mds2-3158",
  "version": "1.0.0",
  "doi": "doi:10.18434/mds2-3158",
  "title": "Stability Study of ac Voltage Source using Josephson Voltage Standards\nData shown in CPEM 2024 abstract",
  "contactPoint": {
    "fn": "Raegan Johnson",
    "hasEmail": "mailto:raegan.johnson@nist.gov"
  },
  "modified": "2024-02-01",
  "status": "available",
  "landingPage": "https://data.nist.gov/od/id/mds2-3158",
  "description": [
    "Dataset for multiple publishable figures in the paper entitled \"Stability Study of ac Voltage Source using Josephson Voltage Standards\"\nin CPEM 2024 abstract"
  ],
  "keyword": [
    "Josephson effect",
    "digital sampling",
    "voltage measurement",
    "voltage fluctuations",
    "humidity dependence."
  ],
  "theme": [
    "Electronics:Superconducting electronicsMetrology",
    "Metrology: Electrical/electromagnetic metrology"
  ],
  "topic": [
    {
      "@type": "Concept",
      "tag": "Electronics:Superconducting electronicsMetrology"
    },
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Metrology: Electrical/electromagnetic metrology"
    }
  ],
  "accessLevel": "public",
  "license": "https://www.nist.gov/open/license",
  "components": [
    {
      "@id": "cmps/Granger_Fig2b.csv",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Granger_Fig2b.csv",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3158/Granger_Fig2b.csv",
      "mediaType": "text/csv",
      "description": "Differential rms voltage amplitude and phase between the JAWS and the NRC ac source and the relative humidity recorded at NIST for a 1V sine wave at 100 Hz ",
      "title": "Granger_Fig2b",
      "size": 513216,
      "checksum": {
        "hash": "9b9cefdf0a5f693ea383d45b8d296f7e0f92264386f7f51e7873c499e8b69bb6",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Granger_Fig1.csv",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Granger_Fig1.csv",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3158/Granger_Fig1.csv",
      "mediaType": "text/csv",
      "title": "Granger_Fig1",
      "size": 142,
      "checksum": {
        "hash": "ea1bedb4ae232275d7fd94fe3b10a55dc3317abbedb16cdefe3e4d122c22c63b",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/3158_README.txt",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "3158_README.txt",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3158/3158_README.txt",
      "mediaType": "text/plain",
      "title": "3158_README",
      "size": 4224,
      "checksum": {
        "hash": "0274bcfb620b7c3c80403929e459ed61a225326925817db1b2770b5de5c29fb2",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Granger_Fig2a.csv",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Granger_Fig2a.csv",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3158/Granger_Fig2a.csv",
      "mediaType": "text/csv",
      "description": "Differential rms voltage amplitude and phase between the JAWS and the NRC ac source and the relative humidity recorded at NIST for a 1V sine wave at 1 kHz ",
      "title": "Granger_Fig2a",
      "size": 161862,
      "checksum": {
        "hash": "fe28fb3d1d4e56615856c78a661c5f603c2b92bf315abf29892230e15c610577",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    }
  ],
  "publisher": {
    "name": "National Institute of Standards and Technology",
    "@type": "org:Organization"
  },
  "language": [
    "en"
  ],
  "bureauCode": [
    "006:55"
  ],
  "programCode": [
    "006:052"
  ],
  "annotated": "2024-02-13T17:23:47.485052",
  "revised": "2024-02-13T17:23:47.485052",
  "issued": null,
  "firstIssued": "2024-02-13T17:23:47.485052"
}