  "_schema": "https://data.nist.gov/od/dm/nerdm-schema/v0.7#",
  "@context": [
    "https://data.nist.gov/od/dm/nerdm-pub-context.jsonld",
    {
      "@base": "ark:/88434/mds2-3189"
    }
  ],
  "@type": [
    "nrdp:DataPublication",
    "nrdp:PublicDataResource",
    "dcat:Dataset"
  ],
  "_extensionSchemas": [
    "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/PublicDataResource"
  ],
  "@id": "ark:/88434/mds2-3189",
  "ediid": "ark:/88434/mds2-3189",
  "version": "1.2.1",
  "doi": "doi:10.18434/mds2-3189",
  "title": "Templates for the Implementation of Rapid GC-MS for Seized Drug and Ignitable Liquid Analyses",
  "contactPoint": {
    "fn": "Briana Capistran",
    "hasEmail": "mailto:briana.capistran@nist.gov"
  },
  "modified": "2024-03-11 00:00:00",
  "status": "available",
  "landingPage": "https://data.nist.gov/od/id/mds2-3263",
  "description": [
    "This dataset contains templates to assist with the implementation and validation of rapid gas chromatography-mass spectrometry (GC-MS) technology for the analyses of seized drugs (probe tip injection) and ignitable liquids (liquid and solid phase microextraction (SPME) injection). The validation package includes plans and workbooks for each application, both of which can be modified to fit the methods and approaches currently utilized in the laboratory. A standard operating procedure (SOP) for the rapid GC-MS system is also included in the validation package. Certain commercial equipment, instruments, or materials are identified in this dataset in order to specify the experimental procedure adequately. Such identification is not intended to imply recommendation or endorsement by the National Institute of Standards and Technology, nor is it intended to imply that the materials or equipment identified are necessarily the best available for the purpose."
  ],
  "keyword": [
    "Rapid GC-MS",
    "Forensics",
    "Seized Drugs",
    "Ignitable Liquids",
    "Validation",
    "Implementation"
  ],
  "topic": [
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Forensics: Trace evidence"
    },
    {
      "@type": "Concept",
      "scheme": "https://data.nist.gov/od/dm/nist-themes/v1.1",
      "tag": "Forensics: Drugs and toxicology"
    }
  ],
  "accessLevel": "public",
  "license": "https://www.nist.gov/open/license",
  "publisher": {
    "name": "National Institute of Standards and Technology",
    "@type": "org:Organization"
  },
  "language": [
    "en"
  ],
  "bureauCode": [
    "006:55"
  ],
  "programCode": [
    "006:052"
  ],
  "_editStatus": "done",
  "theme": [
    "Forensics: Trace evidence",
    "Forensics: Drugs and toxicology"
  ],
  "components": [
    {
      "@id": "cmps/Rapid GC-MS_SOP.docx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Rapid GC-MS_SOP.docx",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3189/Rapid%20GC-MS_SOP.docx",
      "mediaType": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "format": {
        "description": "Word document"
      },
      "description": "Standard Operating Procedures (SOP) for general rapid GC-MS operation and for analysis of seized drugs and ignitable liquids.",
      "title": "Rapid GC-MS SOP",
      "size": 2716516,
      "checksum": {
        "hash": "7bdb7b9c872469681e7dc3f66f561a39b8e228800aa14b248be47c51f54e8288",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Rapid GC-MS Validation Package_Ignitable Liquids Workbook_BLANK.xlsx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Rapid GC-MS Validation Package_Ignitable Liquids Workbook_BLANK.xlsx",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3189/Rapid%20GC-MS%20Validation%20Package_Ignitable%20Liquids%20Workbook_BLANK.xlsx",
      "mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "format": {
        "description": "Excel spreadsheet"
      },
      "description": "Rapid GC-MS Validation Package_Ignitable Liquids Workbook_BLANK (verseion 2)",
      "title": "Rapid GC-MS Validation Package_Ignitable Liquids Workbook_BLANK",
      "size": 198190,
      "checksum": {
        "hash": "accf84194a26fc0a94a1c5a25958337ad4d692c711cc91acb6cf9207637ee49c",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Rapid GC-MS Validation Plan_Ignitable Liquids.docx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Rapid GC-MS Validation Plan_Ignitable Liquids.docx",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3189/Rapid%20GC-MS%20Validation%20Plan_Ignitable%20Liquids.docx",
      "mediaType": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "format": {
        "description": "Word document"
      },
      "description": "Validation plan for rapid GC-MS analysis of ignitable liquids (editable version).",
      "title": "Rapid GC-MS Validation Plan_Ignitable Liquids",
      "size": 90166,
      "checksum": {
        "hash": "6860a99a8dd21c832cfbe95afeaac4c62e5e616422aeed4b0b439b154a0ea418",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Rapid GC-MS Validation Package_Seized Drugs Workbook_BLANK.xlsx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Rapid GC-MS Validation Package_Seized Drugs Workbook_BLANK.xlsx",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3189/Rapid%20GC-MS%20Validation%20Package_Seized%20Drugs%20Workbook_BLANK.xlsx",
      "mediaType": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "format": {
        "description": "Excel spreadsheet"
      },
      "description": "Rapid GC-MS Validation Package_Seized Drugs Workbook_BLANK (version 2)",
      "title": "Rapid GC-MS Validation Package_Seized Drugs Workbook_BLANK",
      "size": 249623,
      "checksum": {
        "hash": "adfbc7f7a3373441f867d318404b8236dd4b54584e5a2182eff54b4e46114727",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/README.txt",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "README.txt",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3189/README.txt",
      "mediaType": "text/plain",
      "title": "README",
      "size": 3321,
      "checksum": {
        "hash": "888e3930e431c21817981915ba47da15d63ba8ab561bf81a761bf671ff2cc032",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    },
    {
      "@id": "cmps/Rapid GC-MS Validation Plan_Seized Drugs.docx",
      "@type": [
        "nrdp:DataFile",
        "nrdp:DownloadableFile",
        "dcat:Distribution"
      ],
      "_extensionSchemas": [
        "https://data.nist.gov/od/dm/nerdm-schema/pub/v0.7#/definitions/DataFile"
      ],
      "filepath": "Rapid GC-MS Validation Plan_Seized Drugs.docx",
      "downloadURL": "https://data.nist.gov/od/ds/mds2-3189/Rapid%20GC-MS%20Validation%20Plan_Seized%20Drugs.docx",
      "mediaType": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "format": {
        "description": "Word document"
      },
      "description": "Validation plan for rapid GC-MS analysis of seized drugs (editable version).",
      "title": "Rapid GC-MS Validation Plan_Seized Drugs",
      "size": 85688,
      "checksum": {
        "hash": "f6ac0a0821cc3562c26ceb4399f372c9e03c8df5a8ced781ee8213fc820879ce",
        "algorithm": {
          "tag": "sha256",
          "@type": "Thing"
        }
      }
    }
  ],
  "authors": [
    {
      "familyName": "Capistran",
      "fn": "Briana A. Capistran",
      "givenName": "Briana",
      "middleName": "A.",
      "affiliation": [
        {
          "title": "National Institute of Standards and Technology",
          "subunits": [
            "Materials Measurement Science Division"
          ],
          "@type": "org:Organization",
          "@id": "ror:05xpvk416"
        }
      ],
      "orcid": "0000-0001-6937-0403",
      "@type": "foaf:Person"
    },
    {
      "familyName": "Sisco",
      "fn": "Edward Sisco",
      "givenName": "Edward",
      "middleName": "",
      "affiliation": [
        {
          "title": "National Institute of Standards and Technology",
          "subunits": [
            "Materials Measurement Science Division"
          ],
          "@type": "org:Organization",
          "@id": "ror:05xpvk416"
        }
      ],
      "orcid": "0000-0003-0252-1910",
      "@type": "foaf:Person"
    }
  ],
  "annotated": "2024-11-07T21:10:51.797746",
  "revised": "2024-11-01T19:46:20.259132",
  "issued": null,
  "firstIssued": "2024-04-08T18:51:08.235035",
  "releaseHistory": {
    "@id": "ark:/88434/mds2-3189/pdr:v",
    "@type": [
      "nrdr:ReleaseHistory"
    ],
    "hasRelease": [
      {
        "version": "1.0.0",
        "issued": "2024-03-11",
        "@id": "ark:/88434/mds2-3189/pdr:v/1.0.0",
        "location": "https://data.nist.gov/od/id/ark:/88434/mds2-3189/pdr:v/1.0.0",
        "description": "initial release"
      },
      {
        "version": "1.0.1",
        "issued": "2024-03-11",
        "@id": "ark:/88434/mds2-3189/pdr:v/1.0.1",
        "location": "https://data.nist.gov/od/id/ark:/88434/mds2-3189/pdr:v/1.0.1",
        "description": "metadata update"
      },
      {
        "version": "1.1.0",
        "issued": "2024-08-21",
        "@id": "ark:/88434/mds2-3189/pdr:v/1.1.0",
        "location": "https://data.nist.gov/od/id/ark:/88434/mds2-3189/pdr:v/1.1.0",
        "description": "spreadsheets updated"
      },
      {
        "version": "1.1.1",
        "issued": "2024-03-11 00:00:00",
        "@id": "ark:/88434/mds2-3189/pdr:v/1.1.1",
        "location": "https://data.nist.gov/od/id/ark:/88434/mds2-3189/pdr:v/1.1.1",
        "description": "metadata update"
      },
      {
        "version": "1.2.0",
        "issued": "2024-03-11 00:00:00",
        "@id": "ark:/88434/mds2-3189/pdr:v/1.2.0",
        "location": "https://data.nist.gov/od/id/ark:/88434/mds2-3189/pdr:v/1.2.0",
        "description": "data update"
      },
      {
        "version": "1.2.1",
        "issued": "2024-11-07",
        "@id": "ark:/88434/mds2-3189/pdr:v/1.2.1",
        "location": "https://data.nist.gov/od/id/ark:/88434/mds2-3189/pdr:v/1.2.1",
        "description": "curator corrected download URLs"
      }
    ]
  },
  "versionHistory": []
}